Mouse over to zoom

RIDEN® RK6006/RK6006-BT 60V 6A 4 Digit Communication 360W Adjustable Digital DC to DC Step Down Voltage Bench Power Supp

Specifications ModelRK6006 RK6006 BTInput voltage range12 68 00VOutput voltage range0 60 00VOutput current range0 6 000AOutput power range0 360WInput voltage measurement resolution0 01VOutput voltagesetting measurement resolution0 01VOutput current setting measurement resolution0 001AInput voltage measurement accuracy± 1 5 digits Output voltage accuracy between setting and measurement± 0 3 3 digits Output currentaccuracybetween setting and measurement± 0 5 5 digits Output ripple typical100mV VPP①Working temperature range 10℃ 40℃External sensor Temperature range 10℃ 100℃ 0℉ 200℉External sensor Temperature accuracy±3℃ ±6℉Constant voltage moderesponse time2ms 0 1A 5A Load Constant voltage mode load regulation± 0 1 2 digits Constant current mode load regulation± 0 1 3 digits Capacity measurement range0 9999 99AhEnergy measurement range0 9999 99WhCapacity and energy statistical error±2 Buck working mode input voltage÷1 1 1②Over temperature protectionSystem temperature80℃Screen brightness setting0 5 6 level in total Screen1 54 inch 240 240 color HD displayCooling fan start conditionOutput current4Aor System temperature45℃Cooling fan shut down conditionOutput current3 9Aand System temperature45℃Weight with package About 0 15kgProduct dimension79 x 43 x 54mmSupport USB communicationyesSupport Bluetooth communication Only RK6006 BT supports① Ripple measurement method noise and ripple are measured at X1 range AC coupling 20MHz of bandwidth on your oscilloscope with a 0 1uF

Banggood

From INR3,343.46

By INR2,835.81

Offers/Coupons

Description: Specifications ModelRK6006 RK6006 BTInput voltage range12 68 00VOutput voltage range0 60 00VOutput current range0 6 000AOutput power range0 360WInput voltage measurement resolution0 01VOutput voltagesetting measurement resolution0 01VOutput current setting measurement resolution0 001AInput voltage measurement accuracy± 1 5 digits Output voltage accuracy between setting and measurement± 0 3 3 digits Output currentaccuracybetween setting and measurement± 0 5 5 digits Output ripple typical100mV VPP①Working temperature range 10℃ 40℃External sensor Temperature range 10℃ 100℃ 0℉ 200℉External sensor Temperature accuracy±3℃ ±6℉Constant voltage moderesponse time2ms 0 1A 5A Load Constant voltage mode load regulation± 0 1 2 digits Constant current mode load regulation± 0 1 3 digits Capacity measurement range0 9999 99AhEnergy measurement range0 9999 99WhCapacity and energy statistical error±2 Buck working mode input voltage÷1 1 1②Over temperature protectionSystem temperature80℃Screen brightness setting0 5 6 level in total Screen1 54 inch 240 240 color HD displayCooling fan start conditionOutput current4Aor System temperature45℃Cooling fan shut down conditionOutput current3 9Aand System temperature45℃Weight with package About 0 15kgProduct dimension79 x 43 x 54mmSupport USB communicationyesSupport Bluetooth communication Only RK6006 BT supports① Ripple measurement method noise and ripple are measured at X1 range AC coupling 20MHz of bandwidth on your oscilloscope with a 0 1uF

0

5 stars

0

4 stars

0

3 stars

0

2 stars

0

1 star

0

Total number of votes

Leave your rating

Do you want to get Offers and discounts via-email?

Sign up now and keep up with our news

Customer - Terms and conditions Customer - Privacy policy

Incredible prices

Here you will find the best offers on the internet in thousands of products.

Security

It's not necessary to give any confidential information. We redirect you to the offering website.

Trust

We work daily to ensure new offers with real discounts.